CIP RC/PT Girder Help

Superstructure Dialog Box

The Superstructure dialog box allows you to view and modify the analytical model in CIP RC/PT Girder.

To open this dialog box, click the Superstructure button on the Model tab. The analytical model is based on physical description of the bridge entered on Geometry tab. The Superstructure dialog box displays the model span distances and locations along spans to hinge points. Support bearings and type of superstructure connection used is also displayed. The user can modify the actual span distances determined from use of the physical description of the bridge to be used for analysis. Analytical models can be based on the properties of either the full bridge or of a single girder (interior or exterior) within the cross-section. When the analysis is based upon an individual girder, LEAPĀ®CIP RC/PT Girder will adjust the substructure properties based upon the proportional ratio of the width of the selected girder to the width of the full cross-section.



Superstructure for Box, T-Beam, or Slab Bridges

Superstructure for I- Girder Birdges

Modifying the Superstructure

Perform the following steps to modify the superstructure:
  1. Select the girder section you want to modify from the drop-down list located in the Girder field.
  2. Select one of the components from the grid by clicking anywhere in its row. A blue arrow displays on the left side of the grid to mark the selection.
  3. Enter the column values in the grid for each section of the structure you want to modify. A definition for each parameter is available below.

Grid Definitions

SettingDescription
Component This noneditable field lists the component type as defined in the Bridge Component Layout dialog box.
Ref Name Enter the component reference name. For more information regarding the naming of components see the Technical Discussion for the Bridge Component Layout dialog box.
Span Distance Enter the analytical distance from this component to the previous support component.
Hinge Distance Enter the analytical distance from this hinge to the previous support component.
Bearing Enter the component bearing. For more information regarding the bearing of components see the Technical Discussion for the Bridge Component Layout dialog box.
Connection Select the connection type from the drop-down list. For more information regarding the specification of component connections see the Technical Discussion for the Bridge Component Layout dialog box.
SettingDescription
Free This keyword connection releases all forces (including vertical shear) and moments. This has the effect of decoupling the superstructure from the substructure, or between adjacent span segments at a span hinge.
Roller This keyword connection releases the longitudinal shear force and the moment about the axis of the support.
Pin This keyword connection releases moment about the axis of the support.
Fix This keyword connection does not release any forces or moments.
Spring Selecting a spring connection opens the Connector Spring Stiffness dialog box.
Area Enter the constant area to be used for this span distance. Note that this value will over-ride the actual interpolated properties computed from using the sections defined on the Geometry tab.
Izz Enter the constant moment-of-inertia to be used for this span distance. Note that this value will over-ride the actual interpolated properties computed from using the sections defined on the Geometry tab.
E-Modulus, E28 Enter the concrete modulus to be used for this span distance. Note that this value will over-ride the modulus defined on the Concrete Materials dialog box.
Unit Weight Enter the concrete unit weight to be used for this span distance. Note that this value will over-ride the unit weight defined on the Concrete Materials dialog box.

Technical Discussion

Generally it is not necessary to modify the superstructure data. Following are a few examples of situations where modifying the superstructure analysis data may be desirable:
  • The analytical model span lengths should be different than that determined by using the bridge layout.
  • When performing a girder analysis and the Automatic Substructure Distribution method (see discussion below) is not appropriate. A more accurate substructure stiffness can be described by creating an appropriate Pier and specifying the reference name of the Pier for the appropriate component.
  • To quickly compare the results of a simpler model by specifying prismatic cross-section properties.
Note: any modifications made to the analysis model on the Superstructure dialog will be lost when changes are made to the physical description of the bridge on the Geometry tab.

When performing an Optional Girder Analysis the model is based upon distances between supports along the centerline of the selected girder. The individual cross-sectional properties of the girder are used for analysis. Typically the substructure (pier and columns as shown on the plans) is defined for the entire bridge and Automatic Substructure Distribution is selected (default) to proportionally reduce the substructure stiffness for the analysis of the individual girder. The Automatic Substructure Distribution reduces the substructure stiffness defined for the full bridge in the proportion of girder width to overall bridge width.

Nomenclature

SettingDescription
Area The area of the current component. (Set Properties Only)
Automatic Substructure Allow CIP RC/PT Girder to automatically determine the substructure stiffness to be used for a girder analysis.
Distribution Girder analysis
Bearing The bearing of the component.
Component Lists the component type as defined in the Bridge Component Layout dialog box.
Connection The type of connection used to tie the component to the bridge.
Ec The modulus of elasticity for the current component. (Set Properties Only)
Fix This keyword connection does not release any forces or moments. (Connection Type)
Free This keyword connection releases all forces (including vertical shear) and moments. This has the effect of decoupling the superstructure from the substructure, or between adjacent span segments at a span hinge.
Girder Modify the bridge frame or a single girder.
Hinge Distance The distance of the hinge from the beginning of the span.
Izz The moment of inertia for the current component. (Set Properties Only)
Pin This keyword connection releases moment about the axis of the support. (Connection Type)
Ref Name The reference name of the component.
Roller This keyword connection releases the longitudinal shear force and the moment about the axis of the support. (Connection Type)
Set Properties Modify the model section properties and materials.
Span Distance The distance to the current component from the beginning of the span.
Spring Define a spring connection opens the Connector Spring Stiffness dialog box. (Connection Type)
Unit Weight The unit weight of the current component. (Set Properties Only)